Visit our global website

continue

Roof hatch with easy access through roof

Flat roof access with roof hatch and ladder from SOGEM

SOGEM Roof hatch offers the optimum and safe way up at flat roofs. The modular roof hatch combination is designed to give the safest and most convenient way to access the roof. The roof hatch is combined with a SOGEM loft ladder and casings after your need, depending on the height of floor separation, completed by the well thought out roof hatch from SOGEM. The roof hatch is easy to use with a good ergonomic handle and 2 strong gas springs on the inside of the hatch. 

For complete weather resistance the hatch is covered with a hot-galvanized steel roof. Thanks to the light gradient on the lid there is no water accumulation on the lid which ensures that water runs from the roof hatch at any time. The snow guard list in the hatch keeps snow and dust outside and lets air circulate in the roof hatch. Prepared for mounting of a cylinder lock. Additional treads made of aluminium in the casing facilitate comfortable access. The aluminium treads are already mounted in the extra casing.



The modular flat roof solution from DOLLE consists of 3 parts:

 

1. Roof Hatch made of hot-dip galvanized steel

Including:

  • Snow guard protection
  • Prepared for mounting of a cylinder lock
  • Anti-slip edge profiles in aluminium
  • 1 x handle - single hand operation
  • 2 x gas springs for easy operation

 

2. Extra casing

Including:

  • Aluminium thread with anti-slip
  • H-profile mouldings and metal fittings.

 

3. SOGEM Loft ladder 

Snow protection in the cover. The snow guard list keeps snow and foliage outside and let air circulate in the hatch box. The double lock is prepared for mounting of a profile cylinder.

 

Easy to operate. The roof hatch is easy to operate with one hand with a good ergonomic handle and 2 strong gas springs on the inside of the hatch. 

 

Rubber buffer and aluminium profile protect the lid. The slight distance to the lid creates a gap for ventilation

 

Tread included in the casing. Additional treads made of aluminium in the casing facilitate the comfortable access. The aluminium treads are already mounted in the extra casing.



MODULAR SYSTEM ROOF HATCH - EASY INSTALLATION

Big advantage of the SOGEM Roof Hatch lies in the modular construction with individual, lightweight components. You install one after the other without use of crane and just by one man.

1. Mount loft ladder

 

2. Add casing on the loft ladder

  • 1 × casing (62,50 - 72,50 cm high)
  • 2 × casing (86,65 - 96,65 cm high)
  • 3 × casing (110,80 - 120,80 cm high)
  • 4 × casing (134,95 - 144,95 cm high)

 

3. Fit the roof hatch - and you are done!


Dimensions

Floor-to-ceiling-height (A)

Standard measurements:

up to 274,0 cm

  

Special measure max. height

 

ISOCLIC PRO 76

332,0 cm

ISOCLIC PRO CONFORT

284,6 cm

FIRE PRO REI45

336,0 cm

REI60 VARIO

244-422 cm

CLICKFIX 76G VARIO

239 - 415 cm

Opening size (B)

 

Standard measurements:

110 / 120 / 130 / 140 cm

Made to measure:

110 - 160 cm

Opening size width (C)

 

Standard measurements:

60 / 70 cm

Made to measure:

60 - 80 cm

Construction height (D)

ISOCLIC PRO 76

min. 28.35 cm - max. 124.95 cm

ISOCLIC PRO CONFORT

min. 28.35 cm - max. 124.95 cm

FIRE PRO REI45

min. 49.15 cm - max. 121.45 cm

REI60 VARIO

min. 49.15 cm - max. 121.45 cm

CLICKFIX 76G VARIO

min. 49.15 cm - max. 121.45 cm

Minimum height (E)

Min. 20 cm above roof

Total height (D + E)

ISOCLIC PRO 76

min. 48.35 - max. 144.95 cm

ISOCLIC PRO CONFORT

min. 48.35 - max. 144.95 cm

FIRE PRO REI45

min. 69.15 - max. 141.45 cm

REI60 VARIO

min. 69.15 cm - max. 141.45 cm

CLICKFIX 76G VARIO

min. 69.15 cm - max. 141.45 cm


FREQUENTLY ASKED QUESTIONS

Our flat roof is an uninsulated solution. The insulation comes from the loft ladder and downwards and here, the u-value depends on the type of loft ladder chosen.

Instead, in flat roof solutions, air circulation is ensured, so that no condensation occurs in the "cavity" between the loft ladder and the flat roof hatch.

When installing the flat roof solution, the casings are mounted first - the roofing board can be mounted directly from the roof and up to 3 cm from the top edge of the casing. When this is done, mount the aluminum strips on the casing before finishing the cover. Please also see the mounting video.

No, when the roof board - aluminum edge moulding is mounted and aluminum edge strips and lids are mounted, you are done. Please see the mounting video.

The trap door to a 120 x 70 cm flat roof hatch weighs 30,4 kg and the frame weighs 9,6 kg.

Drainage from a flat roof is between 2 and 10 degrees, so the incline on the roof is 10 degrees maximum.

We recommend you complete the following maintenance at least once a year:

  • Control all screws and bolts and tighten if.
  • Apply oil to the moving components.
  • Check if the roof hatch opens with little effort and if the gas spring can keep the hatch open. 
  • If a lock is installed test the functionality of the lock.
  • Control if the assemblies between all hatch elements are still assembled and tight.

 

Unfortunately, it is not possible, as it will affect all angles in relation to the opening of both the flat roof hatch and stairs. The incline of the roof can be 10 degrees maximum.

Yes, you can – for adjustment of the top hatch, you can tighten it here to make a real solid connection of the lid.

 


Do you need help ?

 

info@sogem-sa.com  |  Tel. 32 71 25 39 60